Miele KM 326G Cooktop User Manual


 
14 15
There may be a wall at the rear and a wall or tall
units at one side. On the other side, however, no
unit or divider may stand higher than the hob.
Building-in dimensions
Prepare a cut-out in the worktop according to
the dimensions given in the diagram above.
35 7/16" (900 mm)
20
3/16"
(515 mm)
3"
(75 mm)
19 5/16"
(490 mm)
min. 3" (75 mm)
min. 1
3/4"
(45 mm)
33
7/8" (860 mm)
b. The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at
test pressures equal to or less than 1/2 psi
(3.5 kPa).
Warning
The base of the hob will become hot. The gas
connection used must comply with the relevant
national and local regulations.
Important
When the gas hob has been installed, it is
essential to check the main cable is not in
contact with hot parts of the appliance,
otherwise temperature damage to the cable
could occur.
1)
Important
This appliance with the orifices as delivered for
natural gas or LP gas by the manufacturer is
suitable for use till 2000 feet. By installation
above 2000 feet contact your distributor or Miele
USA/Canada and ask for a replacement set with
orifices suitable for your altitude.
Change the orifices as written in the instructions
of the manual.
For Canada only
The gas connection must be made in
accordance with the local codes, or in absence
of local codes, with the current CAN/CA B 149.1
and .2 Inst.
Gas pressures for Canada
Manifold pressure:
– natural gas 4˝ water column
– liquid propane gas 10˝ water column
Nominal rating natural gas 4˝
1)
Burner high setting low setting
kW Btu/hr kW Btu/hr
high-speed burner 2.7 9200 0.35 1200
super high-speed burner 3.4 12000 0.45 1500
2-zone wok burner 4.0 14000 0.17 580
Nominal rating LP gas 10˝ with conversion kit
1)
Burner high setting low setting
kW Btu/hr kW Btu/hr
high-speed burner 2.0 7000 0.40 1300
super high-speed burner 2.7 9200 0.50 2000
2-zone wok burner 3.3 11200 0.18 600
Important
a. The appliance and its individual shut-off valve
must be disconnected from the gas supply
piping system during any pressure testing of
this system at test pressures in excess of
1/2 psi (3.5 kPa).