Chapter 3 – Using the Web Management Software
MultiModem rCell User Guide 43
IP Setup, SNTP Configuration Parameters
General Configuration Group
SNTP Client Enable or disable the SNTP Client to contact the configured server on the UDP port 123 and set
the local time. The default is Disable.
Server Enter the SNTP server name or IP address that the SNTP Client contacts to update the time. No
default.
Polling Time Enter the time, in minutes, after which the SNTP client requests the server to update the time.
Default is 300 minutes.
Time Zone Configuration Group
Time Zone: Enter the time zone. Default is UTC (Universal Coordinated Time, Universal Time). See the following
website for Time Zone information:
http://wwp.greenwichmeantime.com/info/current-time.htm
Time Zone Offset: Enter +/- hh:mm. Default is +00:00. Offset is the amount of time varying from the standard
time of a Time Zone.