Multitech MTCBA-Xx-EN2-GP Oven User Manual


 
Chapter 3 – Using the Web Management Software
MultiModem rCell User Guide 55
3. On the PPP > Wakeup-on-Call screen, configure the following parameters:
Wakeup-on-Call Configuration
Select Enable for Wakeup-on-Call.
Set the Time Delay. You can use the 10 second default.
Enter the Init Strings from the model dependent table described in the Wakeup-on-Call Configuration.
4. To save the changes made on this page, click Submit.
Caller ID Configuration
Enter an SMS to add to the Caller ID list.
Note: Add the SMS message string into the Caller ID list. The SMS message string must not contain any
spaces between words. When the configured string matches the SMS message string, it activates the
Wakeup-on-Call feature.
To save each message as it is entered into the Caller ID list click Add.
Caller Acknowledgement Configuration
Enter a configured string (0 to 40 characters) that is sent to the integrated cellular modem upon receiving
a valid Caller ID from the WAN.
Set the Wakeup Acknowledgement string configuration with the command at+cnma
To save the Acknowledgement Configuration, click the Submit.
5. To ensure your changes go into effect, click Save and Restart. The device saves all the settings and reboots
the computer.