Napoleon Fireplaces GDIZC-N Ventilation Hood User Manual


 
5
W415-0223 / E / 03.05.09
36"
15
1
/
2
"
25"
10
9
/
16
"
5 ½"
AIR INLET
EXHAUST
4
15
/
16
"
15
1
/
2
"
11
5
/
8
"
7
3
/
8
"
3"Ø
44
7
/
8
"
3 SIDED BACKER PLATE
ALUMINUM TRIM
44
7
/8"
36
1
/2"
4 SIDED BACKER PLATE
ALUMINUM TRIM
Provide adequate ventilation air.
Provide adequate accessibility clearance for servicing
and operating the replace insert.
Never obstruct the front opening of the replace
insert.
Objects placed in front of the replace must be kept a
minimum of 48" away from the front face of the unit.
FIGURES 1a-c
Clean out ashes from the inside of the wood-burning replace.
Make sure that the chimney and wood-burning replace
are in a clean and sound condition and constructed of non-
combustible materials. If necessary have any repair work done
by a quali ed person before installing the insert. Remove the
existing replace damper or lock into an open position.
Using screws, attach the replace warning tag (W385-0199)
to the inside of the rebox of the replace into which the insert
is being installed.
The sheet-metal parts of the replace, in which the gas re-
place insert is to be installed, must not be cut.
If the wood-burning factory-built replace has no gas access
hole(s) provided, an access hole of 1½ inch or less may be
drilled through the lower sides or bottom of the replace in
a proper workman like manner. This access hole must be
plugged with non-combustible insulation after the gas supply
line has been installed.
Ensure that existing chimney cleanouts t properly.
The refractory, glass doors, screen rails, screen mesh and log
grates may be removed from the replace before installing
the gas replace insert.
Smoke shelves, shields and baf es may be removed if at-
tached by mechanical fasteners.
The ventilation openings in the replace may be obstructed
by the backer plates, aluminium trim etc. but these parts are
not to be applied so as to have an airtight seal.
WARNING: THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIREPLACE
INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS
ALL ORIGINAL PARTS HAVE BEEN REPLACED AND THE FIREPLACE IS RE-APPROVED BY
THE AUTHORITY HAVING JURISDICTION.
ATTENTION: CE FOYER A ETE CONVERTI AFIN D'ETRE UTILISE SEULEMENT COMME
FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE POUR BRULER DU BOIS OU TOUT
AUTRE COMBUSTIBLE SOLIDE, SANS QUE TOUTES LES PIECES ORIGINALES AIENT ETE
REMPLACEES ET QUE LE FOYER SOIT APPROUVE DE NOUVEAU PAR
LES AUTORITES
AYANT JURIDICTION.
W385-0199
14"
15
1
/
2
"
20
3
/
4
"
3 SIDED BACKER PLATE - FRONT VIEW
4 SIDED BACKER PLATE - FRONT VIEW
TOP VIEW
3 & 4 SIDED BACKER PLATES - SIDE VIEWS
INSTALLATION