Napoleon Fireplaces GDIZC-N Ventilation Hood User Manual


 
9
W415-0223 / E / 03.05.09
The on-off switch is located behind the left side control
door.
Purge all gas lines with the glass door open. Assure that a
continuous gas ow is at the burner before closing the door.
Allow several minutes (5-15) for the ame to stabilize after
ignition.
Do not operate the main burner of the insert
with the door removed.
When lit for the rst time, the replace will emit a slight odour
for a few hours. This is a normal temporary condition caused
by the "burn-in" of paints and lubricants used in the manufac-
turing process and will not occur again. Simply open a window
to suf ciently ventilate the room. After extended periods of
non-operation such as following a vacation or a warm weather
season, the replace may emit a slight odour for a few hours.
This is caused by dust particles in the heat exchanger burning
off. Open a window to suf ciently ventilate the room.
PURGE THE GAS LINE WITH THE GLASS DOOR OPEN.
7. Turn gas knob counter-clockwise
to pilot.
8. Depress slightly and hold gas knob while lighting the
pilot with the push button ignitor. Keep knob depressed for
one minute, then release. If pilot does not continue to burn,
repeat steps 3 through 7.
9. With pilot lit, depress and turn gas knob counter-clockwise
to on.
10. If equipped with ame adjustment valve, push and turn
knob to high.
11. If equipped with remote on-off switch/thermostat, main
burner may not come on when you turn valve to on. Remote
switch must be in the on position to ignite burner.
12. Turn on all electric power to the replace.
A. This replace is equipped with a pilot which must be lit by
hand. While following these instructions exactly.
B. Before operating smell all around the replace area for gas
and next to the oor because some gas is heavier than air
and will settle on the oor.
C. Use only your hand to turn the gas control knob. Never use
tools. If the knob will not turn by hand, do not try to repair
it. Call a quali ed service technician. Force or attempted
repair may result in a re or explosion.
D. Do not use this replace if any part has been under water.
Immediately call a quali ed service technician to inspect
the replace and replace any part of the control system
and any gas control which has been under water.
• Turn off all gas to the replace.
• Open windows.
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the re depart-
ment.
When lighting and re-lighting, the gas knob cannot be turned
from pilot to off unless the knob is depressed slightly.
1. Stop! Read the above safety information on this label.
2. Turn off all electric power to the replace.
3. Turn the gas knob clockwise to off.
4. Wait ve (5) minutes to clear out any gas. If you smell gas
including near the oor. Stop! Follow "B" in the above safety in-
formation on this label. If you don't smell gas go the next step.
5. If replace is equipped with ame adjustment valve turn
clockwise to off.
6. Find pilot located in front of back log.
2. Push in gas control knob slightly and turn clockwise
to off. Do not force.
1. Turn off all electrical power to the unit if service is to be
performed.
TURN OFF THE GAS AND UNPLUG ELECTRICAL
POWER BEFORE SERVICING THE FIREPLACE INSERT!
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing. This insert
and its venting system should be inspected before use and
at least annually by a quali ed service person. The replace
area must be kept clear and free of combustible materials,
gasoline or other ammable vapours and liquids. The ow of
combustion and ventilation air must not be obstructed.
1. In order to properly clean the burner and pilot assembly,
remove the logs exposing both assemblies.
2. Keep the control compartment, logs, burner, air shutter
opening and the area surrounding the logs clean by vacu-
uming or brushing, at least once a year.
3. Check to see that all burner ports are burning. Clean out
any of the ports which may not be burning or are not burn-
ing properly.
4. Check to see that the pilot ame is large enough to engulf
the thermocouple on one leg and reaches toward the burner
on the other leg.
5. Replace the cleaned logs.
6. Check to see that the main burner ignites completely on
all openings when the gas knob for the burner is turned on.
A 5-10 second total light-up period is satisfactory. If ignition
takes longer, consult your Napoleon dealer/distributor.
7. Check that the door gasketing is not broken or missing.
Replace if necessary.
OPERATION / MAINTENANCE
WHAT TO DO IF YOU SMELL GAS:
OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING:
LIGHTING INSTRUCTIONS
TO TURN OFF GAS
MAINTENANCE
FIGURE 19
FIGURE 20
FLAME ADJUSTMENT
KNOB
ON/OFF KNOB