Pelco CM9740-UPG-8312 Frozen Dessert Maker User Manual


 
C1547M (7/03) 7
b. Remove the current System Manager program:
(1) In the Windows taskbar, click the Start button.
(2) Highlight Settings and then click Control Panel.
(3) Double-click the Add/Remove Programs icon.
(4) For a PC running Windows 95/98/NT: On the Install/Uninstall tab, click the System Manager 9760 program
and then click the Add/Remove button. A dialog box appears indicating the progress of the removal of the
System Manager program. When removal of the System Manager program completes, click the OK button.
For a PC running Windows 2000 or XP: Click Change or Remove Programs. In the Currently installed
programs box, click the System Manager 9760 program and then click the Remove button. At the system
prompt asking you whether you are sure you want to remove the System Manager program, click Yes. The
System Manager program is removed.
NOTE: If, during the removal of the System Manager program, Confirm File Deletion boxes appear asking you to
remove shared .dll files, click Yes. Then continue with the removal of the System Manager program.
c. Install version 8.03.012 of the System Manager program, which is provided on CD-ROM. (For System Manager
installation instructions, refer to the CM9760-MGR System Management Software Installation/Operation manual.)
3. Using the READ utility of the System Manager program, load the current configuration files using the floppy disk from
step 1d(3) into the System Manager database. The configuration files are upgraded to version 8.03.012 in the System
Manager database. (For information about the READ utility, refer to the CM9760-MGR System Management Software
Installation/Operation manual.)
4. Using the WRITE utility of the System Manager program, copy the new version of configuration files to a floppy disk. To
prevent overwriting the old version of configuration files,
do not use the same floppy disk that was used in step 1d(3).
Copy the new version of configuration files to a different floppy disk, and label the disk using a unique name. Note that
you will need to use the disk containing the new version of configuration files later in this procedure as directed.
(For information about the WRITE utility, refer to the CM9760-MGR System Management Software Installation/Operation
manual.)
5. Using the AT-compatible keyboard attached to the initial CC1 being upgraded, do the following:
a. At the C:\9740 prompt, rename the CM9740.EXE file to CM9740.OLD by entering:
rename cm9740.exe cm9740.old
b. Verify that the CM9740.EXE file was renamed to CM9740.OLD by entering:
dir/w
c. Delete the existing configuration files by entering:
del filename.xxx
where
filename
is the configuration file name and
xxx
is the extension of the file name (mon, cam, mac, scp, alm,
gpi, pin, sym, lcm, or idn). For example, if the file name is node5, then the commands used to delete configuration
files are as follows:
del node5.mon
del node5.cam
del node5.mac
del node5.scp
del node5.alm
del node5.gpi
del node5.pin
del node5.sym
del node5.lcm
del node5.idn