Scotsman Ice AFE325 Ice Maker User Manual


 
Final Check List & Initial Start Up
1. Is the machine located indoors where the
temperature limitations are not exceeded?
2. Is there at least 6" clearance on the left side and
the back of the cabinet for adequate air flow?
3. Is the water supply adequate, and has a shut off
valve been installed?
4. Is the cabinet level?
5. Have all of the electrical and drain connections
been made?
Initial Start Up
1. Remove the following parts:
Top panel
Bin door
Rubber molding
Left molding cover
Left track
Upper front panel
Upper baffle
Left side panel
Front louvered panel
Control box cover
the top panel.
2. Open the water shut off valve.
3. Watch the water fill the reservoir. Check that it
flows in and fills the reservoir near to the mark
molded into the side of the reservoir. Check that
the float shuts off the water flow when the tank is
full. Check for leaks. Tighten hose clamps as
needed.
4. Plug the unit in or switch on the electrical power.
5. Switch the master switch to ON.
6. Let the machine operate, listen for any unusual
noises. If needed, reposition tubing & panels to
eliminate vibration.
After the unit has been operating for about 10
minutes, there should be enough ice in the bin to
test the bin thermostat.
7. Pick up some ice and hold it up against the
bottom of the ice thermostat tube.
8. After a short time the bin thermostat should
switch the machine off.
9. Pour water into the bin and check that the drain
does not leak but drains the water rapidly.
10. Replace all panels.
11. Explain to the user the maintenance
requirements and operation of the machine.
12. Fill out the Warranty Registration and
Customer Evaluation form. Mail it to Scotsman.
13. Leave the service manual with the owner/user
and explain who should be called if service is
needed.
Adjustment Altitude (ft.
above seal level)
Amount of
adjustment from
factory setting
Range
Screw CW
2,000 35
o
4,000 90
o
6,000 145
o
8,000 190
o
Note: For High Altitude Installations an Altitude
Adjustment May Be Required:
(11-0354-01, 20 Ranco brand bin thermostats only)
AFE325
August 1994
Page 6