User Operation
The AFE325 is an automatic ice flaked machine.
All it requires is cool air, clean water, a drain, and
an adequate supply of electrical power.
The user must regularly sanitize and clean the
machine.
Component Location & Function
Evaporator. This is a vertical cylinder full of water
and refrigerated. Also in the cylinder is a slowly
rotating auger. The auger forces the ice up the
evaporator walls and compresses it at the top. The
resulting flaked ice then falls by gravity into the ice
storage bin.
Water Reservoir. The water reservoir contains the
inlet float valve and the water level sensor. The
float valve controls the flow of water into the
reservoir.
Water Pressure Cut Out Switch: The purpose of
this switch is to stop the ice maker if the water
supply fails.
Condenser. The AFE325 uses an air cooled
condenser. It blows air out, away from the fan
motor. The heat removed from the water is
exhausted from the condenser.
Compressor. The refrigeration system
compressor provides the force to move the
refrigerant around the system.
Auger Drive. The auger drive
is a direct drive gear reducer.
AFE325
August 1994
Page 7