SPECIFICATIONS COMBINATION OVEN
PAGE 4OPERATOR’S MANUAL 1180963
SPECIFICATIONS
SPECIFICATIONS
DIMENSIONS
B
A
E
C
D
J KI
F
G
H
Internal Dimensions: 20.75" Wide, 31.75" Deep, 22" High
Model Cabinet Width (A) Overall Width (B) Leg Height (C) Overall Height (D) Overall Depth (E)
CG90-1 38" 39.6" 25.9" 59.1" 40.3"
Water Connection
3/8" NPT (Female)
Gas Supply Connection
3/4" NPT (Male)
Drain Tube
2" OD
Model
From Right (F) Above Floor (I) From Right (G) Above Floor (J) From Right (H) Above Floor (K)
CG90-1 12.6" 33.9" 17.5" 29.5" 20.2" 28.9"
GAS
Burners total 90,000 BTU. Supply pressure should be > 7" W.C. for natural gas or > 11" W.C. for propane.
One 3/4" NPT male connector located on back, 17.5" from right side, 29.5" above floor (see above figure).
WATER
Cold water consumption is regulated to approximately 0.5 gallons per minute. Water pressure 30 psi (205
kPa) minimum, 60 psi. (410 kPa) maximum. To minimize service problems and to meet warranty
requirements, a water treatment system (softener) is recommended if water quality does not meet the
following specifications: total dissolved solids (TDS) 60 ppm, hardness 2 grains or 35 ppm, pH factor7.0 to
7.5. Install a water treatment system (softener) if necessary. Connector is a 3/8" female NPT "tee" located
on the back of the oven, 12.6" from right side, 33.9" above floor (see above figure).
DRAIN
Drain line is a 2" OD tube extending from the back of the oven, 20.2" from right side, 28.9" above floor (see
above figure). Drain outlet must be unobstructed and free-venting to atmospheric pressure! See page 11.