DIMENSIONS AND SPECIFICATIONS continued
Base Model Designations & Total Input Rates
Model # Description
Input BTU/Hr
Natural
Gas
Propane
Gas
X24-4S 24” (610mm) nominal size unit, 4 open burners, storage base 120,000 104,000
X24-4L 24” (610mm) nominal size unit, 4 open burners, space saver oven 145,000 129,000
X36-6S 36” (914mm) nominal size unit, 6 open burners, storage base 180,000 156,000
X36-6R 36” (914mm) nominal size unit, 6 open burners, standard oven 213,000 185,000
X60-10SS 60” (1524mm) nominal size unit, 10 open burners, 2 storage bases 300,000 260,000
X60-10RS 60” (1524mm) nominal size unit, 10 open burners, standard oven, storage base 333,000 289,000
X60-10RR 60” (1524mm) nominal size unit, 10 open burners, 2 standard ovens 366,000 318,000
X60-6R24SS
60” (1524mm) nominal size unit, 6 open burners, 24” (610mm) Raised Griddle/Broiler,
2 storage bases
203,000 189,000
X60-6R24RS
60” (1524mm) nominal size unit, 6 open burners, 24” (610mm) Raised Griddle/Broiler,
standard oven, storage bases
246,000 218,000
X60-6R24RR
60” (1524mm) nominal size unit, 6 open burners, 24” (610mm) Raised Griddle/Broiler,
2 standard ovens
279,000 247,000
Rates are for installations up to 2000’ (610m) above sea level
INTRODUCTION
1. Check crate for possible damage sustained during transit.
Carefully remove unit from crate and again check for
damage. Any damage to the appliance must be reported
to the carrier immediately.
2. The wires for retaining packing material must be
removed from units. Any protective material covering
stainless steel parts must also be removed.
3. All equipment is supplied with 6” (152mm) legs unless
specied to be dais for cove base mounting, casters or
deck mount anged feet. 60” (1524mm) wide units have
legs factory mounted. Base mounting is required when
range is being installed on a combustible oor.
4. The type of gas and supply pressure that the equipment
was set-up for at the factory is noted on the rating plate
and on the packaging. This type of gas supply must be
used.
5. Do not remove permanently axed labels, warnings or
rating plates from the appliance, for this may invalidate
the manufacturer’s warranty.
Rating Plate
All burner input rates are shown on the rating plate, which is
located behind the lower front drop down panel under the
oven door.