Taylor C300 NP Frozen Dessert Maker User Manual


 
5
Model C300 NP Safety
CAUTION: This unit is pressurized when
in operation. The control switch must be in the OFF
position until the unit is completely assembled. No
part should ever be removed from the machine while
it is in operation. No parts should be removed until
the control switch has been turned to the OFF
position. Failure to follow this instruction may result
in severe personal injury from hazardous moving
parts or from the impact of propelled parts.
S DO NOT allow untrained personnel to
operate this machine.
S DO NOT operate the freezer unless all
service panels and access doors are
restrained with screws.
S DO NOT remove any internal operating
parts (example: freezer door, beater,
scraper blades, etc.) unless all control
switches are in the OFF position.
Failure to follow these instructions may result in
severe personal injury from hazardous moving parts.
This unit has many sharp edges that can
cause severe injuries.
S DO NOT put objects or fingers in the door
spout. This may contaminate the product
and cause severe personal injury from blade
contact.
S USE EXTREME CAUTION when removing
the beater asssembly. The scraper blades
are very sharp.
This freezer must be placed on a level
surface. Failure to comply may result in personal
injury or equipment damage.
Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
and must be followed accordingly. Please refer to
the cleaning section of this manual for the proper
procedure to clean this unit.
DO NOT obstruct air intake and discharge openings:
Air cooled units require a minimum of 3” (76 mm) of
air space on the rear and left side to the top of the
unit, 0” on the right side, and a minimum of 12” (305
mm) air clearance to the ceiling. This is required to
allow for adequate air flow through the condenser(s).
Failure to follow this instruction may cause poor
freezer performance and damage to the machine.
This freezer is designed to operate indoors, under
normal ambient temperatures of 70°-75°F
(21°-24°C). The freezer has successfully performed
in high ambient temperatures of 104°F (40°C) at
reduced capacities.
NOISE LEVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of
1.0 meter from the surface of the machine and at a
height of 1.6 meters from the floor.