Taylor C302 Blender User Manual


 
17
Model C302 Important: To the Operator
Press the AUTO (- ->) key to move to the next
screen. The next screen will indicate when the fault
was satisfied.
FAULT HISTORY 2
02/25/04 14:06:19
RESTORED FROM FAULT
PAGE 2 + + + - - - SEL
Press the MENU (SEL) key to return to the
OPERATOR MENU.
Screen H is RINSE/SANITIZE. This screen allows
the operator to rinse or sanitize the freezing
cylinder(s).
RINSE / SANITIZE
RINSE SANITIZE EXIT
---
<- - - -> SEL
Use the AUTO (- ->) and OFF (<- -) keys to select
either RINSE or SANITIZE, and then press the
MENU (SEL) key.
SANITIZE
LEFT SIDE YES NO
---
<- - - -> SEL
Use the cursor keys to select YES or NO, then
press the MENU (SEL) key.
SANITIZE
RIGHT SIDE YES NO
---
<- - - -> SEL
Repeat for the right side of the unit.
Screen I is SERVICE MENU. This screen allows
the authorized service technician to access service
information. Press the MENU (SEL) key to return to
the OPERATOR MENU.
OPERATOR MENU
ABCDEFGHI
SERVICE MENU
<- - - -> SEL
Syrup Out Indicator
AUTO MODE AUTO
OUT SYRUP OK
CO2-OK WATER-OK
If the word “OUT” appears in one of the columns
next to the word “SYRUP”, it indicates a lack of
syrup or syrup pressure being supplied for the
indicated freezing cylinder. If the unit is in the AUTO
or PRIME modes, the product light will illuminate
and a warning tone will sound for that freezing
cylinder. At this time, replace the appropriate
bag-in-the-box. As a safety feature, the refrigeration
system automatically stops to prevent a freeze-up in
the freezing cylinder (barrel).
If a syrup out condition occurs on one barrel, that
barrel will enter the HOLD mode. During the HOLD
mode, refrigeration remains off, the beater continues
to run, and the CO
2
solenoid for that barrel is closed
to prevent the dispensing of product. The opposite
barrel will not be affected.