Taylor C302 Blender User Manual


 
30
Model C302Operating Procedures
080307
Rinsing
Note: The following instructions are for one pair of
freezing cylinders under an LCD. After the
instructions are complete, repeat for the two freezing
cylinders on the other side of the machine under the
other LCD.
Step 1
To place the left cylinder in the RINSE mode, press
the MENU (SEL) key. Move the cursor by pressing
the AUTO (- ->) key until the third line indicates
RINSE / SANITIZE.
OPERATOR MENU
ABCDEFGH
I
RINSE / SANITIZE
<- - - -> SEL
Step 2
Press the MENU (SEL) key. Move the cursor under
“RINSE” by pressing the OFF (<- -) key twice.
RINSE / SANITIZE
RINSE SANITIZE EXIT
----
<- - - -> SEL
Step 3
Pressing the MENU (SEL) key will give you the
option for rinsing the left freezing cylinder. Move the
cursor under the word “YES”. Pressing the MENU
(SEL) key at this time will start the beater motor and
deliver water and CO
2
to the left cylinder.
RINSE
LEFT SIDE YES NO
---
<- - - -> SEL
Step 4
Allow the rinse water to flow into the cylinder until it
is approximately 2/3 full. With a pail under the door
spout, open the draw valve and drain the rinse
water. Repeat this procedure until the rinse water
being drawn is clear.
Step 5
Repeat Steps 3 - 4 for the right freezing cylinder.
Note: There is a left and a right freezing cylinder for
each LCD.
RINSE
RIGHT SIDE YES NO
---
<- - - -> SEL
Step 6
When draining is complete, press the OFF (<- -)
key.
Step 7
Repeat these steps for the other side of the
machine.
Cleaning
Note: The following instructions are for one pair of
freezing cylinders under an LCD. After the
instructions are complete, repeat for the two freezing
cylinders on the other side of the machine under the
other LCD.
Step 1
Prepare two gallons (7.6 liters) of an approved
cleaning solution (examples: Kay-5® or Stera-
Sheen®). USE WARM WATER AND FOLLOW THE
MANUFACTURER'S SPECIFICATIONS.
Important: Make sure the cleaner is completely
dissolved.
Step 2
Pour the cleaning/sanitizing solution into a clean,
empty pail. Place the syrup line with the old syrup
connector into the pail of cleaner.
Step 3
To place the left freezing cylinder in the SANITIZE
mode, press the MENU (SEL) key. Move the cursor
by pressing the AUTO (- ->) key until the third line
indicates RINSE / SANITIZE. Press the MENU
(SEL) key. Move the cursor under the word
“SANITIZE”.
RINSE / SANITIZE
RINSE SANITIZE EXIT
-----
<- - - -> SEL