Taylor C302 Blender User Manual


 
29
Model C302 Operating Procedures
Step 15
Close the illuminated display when complete.
Replace the panels and the hood, and attach with
screws. Install the front drip tray and the splash
shield on the front of the freezer.
Figure 41
120 Day Closing Procedure
We recommend that the machine be completely
disassembled and cleaned at least every 120 days
using the following procedures.
ALWAYS FOLLOW LOCAL HEALTH CODES
To disassemble the Model C302, the following items
will be needed:
S Two cleaning pails
S Necessary brushes (provided with freezer)
S Cleaner
S Single service towels
Draining Product From the
Freezing Cylinders
Step 1
Press the BEATER (- - -) key. This will allow the
beater to operate and CO
2
pressure will be
maintained to push the product from the freezing
cylinder. Open the draw valve and drain the product
from the machine until the CO
2
begins to jet.
Figure 42
Step 2
When all the product has been drained from the
freezing cylinder, close the draw valve and press the
OFF (<- -) key. Discard this product.
Figure 43
Step 3
Repeat Steps 1 and 2 for the other freezing
cylinders.