20
Model C713Important: To the Operator
The MIX LEVEL AUDIBLE option, when enabled,
will alert the operator with an audible tone when
there is mix low or mix out condition. The following
screen is displayed upon selecting this option.
(See Figure 25.)
MIX LEVEL AUDIBLE
> Enable
Disable
Figure 25
Disable the audible tone feature by selecting the UP
arrow symbol to move the arrow to Disable. Select
the SEL symbol to save the new setting and return
to the Menu. The control panel icons for Mix Low
and Mix Out will light as the mix level drops in the
hopper but the audible tone will be disabled.
The LOCKOUT HISTORY screen displays a history
of the faults. (See Figure 26.)
LOCKOUT HISTORY
07/27/04 12:58
< HPR THERM FAIL
> EXIT
Figure 26
Use the arrow symbols to advance forward or
backward to view each screen. The following list
indicates the variable messages that may appear.
Faults Occurring While in AUTO Mode
HPR>41F (5C) AFTER 4 HR - The mix temperature
in the hopper was above 41_F(5_C) more than four
hours.
BRL>41F (5C) AFTER 4 HR - The mix temperature
in the freezing cylinder was above 41_F(5_C) more
than four hours.
HPR>41F (5C) AFTER PF - The mix temperature in
the hopper was above 41_F(5_C) more than four
hours following a power failure.
BRL>41F (5C) AFTER PF - The mix temperature in
the freezing cylinder was above 41_F(5_C) more
than four hours following a power failure.
HPR>45F (7C) AFTER 1 HR - The mix temperature
in the hopper was above 45_F(7_C) more than one
hour.
BRL>45F (7C) AFTER 1 HR - The mix temperature
in the freezing cylinder was above 45_F(7_C) more
than one hour.
HPR>59F (15C) - The mix temperature in the
hopper exceeded 59_F(15_C).
BRL>59F (15C) - The mix temperature in the
freezing cylinder exceeded 59_F(15_C).
Note: Refer to your local health codes regarding
temperature recommendations for procedures to
follow if these fault screens appear.