Taylor C716 Freezer User Manual


 
36
Models C708 & C716Operating Procedures
Step 13
Place the agitator on the agitator drive shaft
housing. (See Figure 48.)
12182
Figure 4 8
Note: If agitator should s top turning during nor mal
operation, with sanitized hands, remove agitator
from agitator drive shaft housing and brush c lean
with sanitizing solution. Install the agitator back onto
the agitator drive shaft housing.
Step 14
Remove the cotter pin from the pump. Install the top
end of the feed tube into the pump assembly. Place
the cotter pin in position on the outlet fitting of the
pump assembly. (See Figure 49.)
Figure 4 9
Repeat these steps for the other side of the
Model C716.
Priming
Note: Use only FRESH MIX when priming the
freezer.
Step 1
Place an e mpty mix pail beneath the door s pout(s).
Pour 2-1/2 gallons (9.5 liters) of FRESH mix i nto the
mix hopper and allow it to flow into the freezing
cylinder.
Step 2
Open the draw valve to remove all sanitizing
solution. When only fresh mix i s flowing, close the
draw valve.
Note: Momentarily open the center draw valve to
remove sanitizer from the center door spout (C716
only).
Step 3
When mix stops bubbling down into the freezing
cylinder, remove the cotter pin from the outlet fitting
of the mix pump. Insert the outlet end of the mix
feed tube into the mix inlet hole in the mix hopper .
Place the inlet end of the mix feed tube into the
outlet fitting of the m ix pum p. Secure with c otter pin.