GB
20
Models VTN VT VTC B VT CM VR VTC
DC DUAL.1 622 DC
Hob dimensions
Height (mm) 120 163 120 85 120 120
Length (mm) 590 600 600 600 600 600
Width (mm) 510 510 510 510 510 510
Dimensions of the placement in the unit
Length (mm)
(L)
570 580 580 580 580 580
Width (mm)
(W)
492 492 492 492 492 492
Depth (mm) 115 117 115 60 115 115
Configuration
Double radiant hotplate
700/2100W circuit
1 1 1 1
Double radiant hotplate
700/1700W circuit
Double radiant hotplate
1400/2000W circuit
2100W radiant hotplate
1 1
1800W halogen
radiant hotplate
1800W radiant hotplate
2 1 2 2
1500W radiant hotplate
2
1200W radiant hotplate
1 1 2 2 1
3 kW rapid burner 1
1.75 kW semi-rapid 1
burner
Electrics
Nominal Power
(W) for 230 V*
6.900 3.300 6.300 6.000 6.700 6.900
Supply
voltage (V)
SEE THE APPLIANCE’S RATING PLATE
Frequency (Hz) 50-60 50-60 50-60 50-60 50-60 50-60
Gas
Power
Maximum (kW) 4,75
* For voltages other than 230 V please consult the appliance’s rating plate
TR
641
65
600
510
560
490
61
1
2
1
50-60
6.200