English 1
Safety
PLEASE READ CAREFULLY
Gas Type Verification
Rangetops are shipped by the factory to operate on natural
gas. Verify the type of gas supplied to the location. Ensure
that the appliance is connected to the type of gas for which
it is certified. All models are certified for use with natural
gas. Field conversion of the appliance for use with propane
gas supply will require a conversion kit (PLPKIT). Field
conversion must be done by qualified service personnel
only.
IMPORTANT:
When installing against a combustible surface, a Low
Backguard is required. A THERMADOR
®
Low Backguard
must be purchased separately. See the Installation Manual
for backguard and installation information.
When using the Flush Island Trim, THERMADOR
recommends a minimum 12” (305 mm) rear clearance to a
combustible surface (see the Installation Manual for
clearance requirements). Clearances from non-
combustible materials are not part of the ANSI Z21.1 scope
and are not certified by CSA. Clearances of less than 12”
(305 mm) must be approved by the local codes and/or by
the local authority having jurisdiction.
Before using the rangetop, ensure that it is equipped with a
proper backguard. Refer to the Installation Manual
accompanying this appliance for more information.
IMPORTANT SAFETY INSTRUCTIONS
Read and Save These Instructions
WARNING:
If the information in this manual is not
followed exactly, a fire or explosion may
result causing property damage, personal
injury or death.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
WARNING:
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
Refer to this manual. For assistance or additional
information consult a qualified installer, service agency,
manufacturer (dealer) or the gas supplier.
For Massachusetts Installations:
1. Installation must be performed by a qualified or
licensed contractor, plumber or gas fitter qualified or
licensed by the state, province or region where this
appliance is being installed.
2. Shut-off valve must be a “T” handle gas cock.
3. Flexible gas connector must not be longer than 36”
(914mm).
CAUTION:
When connecting the unit to propane gas, make certain
the propane gas tank is equipped with its own high-
pressure regulator in addition to the pressure regulator
supplied with the rangetop. The maximum gas
pressure to this appliance must not exceed 14.0”
water column (34.9 mb) from the propane gas tank to
the pressure regulator.
WARNING:
To avoid possible burn or fire hazard, a back guard
designed specifically for this rangetop must be installed
whenever the rangetop is used.