A. Set unit in its final location. Be sure there is
adequate ventilation in your room. Under extreme heat
conditions, (100°F+, 38°C+), you may want to install an
exhaust fan.
Warning
Warranty is void if ventilation is insufficient.
B. Proper leveling of your True cooler is critical to
operating success (for non-mobile models). Effective
condensate removal and door operation will be effected
by leveling.
C. The cooler should be leveled front to back and side
to side with a level.
D. Ensure that the drain hose or hoses are positioned in
the pan.
E. Free plug and cord from inside the lower rear of the
cooler (do not plug in).
F. The unit should be placed close enough to the
electrical supply so that extension cords are never used.
Warning
Compressor warranties are void if the unit is more
than 7 ft. (2.1m) from plug-in connection.
LEVELING
A. Place packing material behind cabinet as a
cushion. Carefully lay the unit on its back to
remove skid.
When lifting unit remember to
leave the cabinet upright for 24 hours before
plugging into power source.
B. Remove skid by unscrewing all base rail anchor
brackets. Place skid to the side.
C. Carefully lift cabinet upright.
LOCATING
Removing
skid from
bottom of
cabinet.
REMOTE UNITS (This section applies to
remotes only!)
Remote cabinets must be ordered as remote.
We do not recommend converting from a
standard self contained to remote system.
All remote cabinets must be hard wired.
No castors available.
All remote cabinets come standard using 404A
refrigerant.
All remote units come standard with expansion
valve, liquid line solenoid, heated condensate
pan, and defrost timer when applicable.
Contact True Technical Service for BTU
requirements.
No wiring necessary between cabinet and
condensing unit.
All remote condensing units purchased from
True are 208/230 volts single phase.
If you have any questions regarding this
section, please call True at 1-(800)-325-6152.
Some units have a
polyester strap that
secures the cabinet to
the shipping skid. Cut
this polyester strap
and remove the
wood skid.
Polyester Strap