A. Before your new unit is connected to a
power supply, check the incoming voltage with a
voltmeter. If anything less than 100% of the rated
voltage for operation is noted, correct immediately.
B. All units are equipped with a 7 ft. (2.1m) service
cord, and must be powered at proper operating
voltage at all times. Refer to cabinet data plate
for this voltage.
True requires that a sole circuit be dedicated for the
unit. Failure to do so voids warranty.
WARNING
Compressor warranties are void if compressor burns out due to
low voltage.
WARNING
Power supply cord ground should not be removed!
NOTE
To reference wiring diagram - Remove lower rear grill. Wiring
diagram is positioned on the inside cabinet wall.
ELECTRICAL INSTRUCTIONS
INSTALLATION / OPERATION INSTRUCTIONS
A. The compressor is ready to operate. Plug in the unit.
B. The temperature control is set at the No. 4 position
from the factory. Allow unit to function several
hours, completely cooling cabinet before changing
the control setting.
C. Excessive tampering with the control could lead to
service difficulties. Should it ever become necessary
to replace temperature control, be sure it is ordered
from your True dealer or recommended service
agent.
NOTE
If the unit is disconnected or shut off, wait five minutes before
starting again.
RECOMMENDATION
Before loading product we recommend you run your True unit empty
for two to three days. This allows you to be sure electrical wiring
and installation are correct and no shipping damage has occurred.
Remember, our factory warranty does not cover product loss!
REPLACEMENT PARTS
TRUE maintains a record of the cabinet serial number for your unit.
If at any time during the life of your display case, a part is needed,
you may obtain this part by furnishing the model number and serial
number to the company from whom you purchased the cabinet. Call
Toll-Free: (800)-424-TRUE (Direct to Parts Department). (800)-325-
6152 (U.S.A. & Canada only) or call: (636)-240-2400.
STARTUP
Serial Number
REMOTE UNITS (This section applies to remotes only!)
Remote cabinets must be ordered as remote.
We do not recommend converting from a
standard self contained to remote system.
All remote cabinets must be hard wired.
No castors available.
All remote cabinets come standard using 404A
refrigerant.
All remote units come standard with expansion
valve, liquid line solenoid, heated condensate
pan, and defrost timer when applicable.
Contact True Technical Service for BTU
requirements.
No wiring necessary between cabinet and
condensing unit.
All remote condensing units purchased from
True are 208/230 volts single phase.
If you have any questions regarding this section, please call
True at 1-(800)-325-6152.