INSTALLATION / OPERATION INSTRUCTIONS
VENTILATION
A. Set unit in its final location. Be sure there is
adequate ventilation in your room. Maximum ambient
operating temperature is 75˚F / 55% humidity.
Warning
Warranty is void if ventilation is insufficient.
SEALING CABINET TO FLOOR
Step A - Position Cabinet
When positioning cabinet into a final location make
sure there are no obstructions in front of the intake and
exhaust areas. These areas are located in the front and
back of the cabinet.
Step B - Level Cabinet
Cabinet should be level, side to side and front to back.
Place a carpenter’s level in the interior floor in four
places:
1. Position level in the inside floor of the
unit near the front. (Level should be parallel
to cabinet front). Level cabinet.
2. Position level at the inside rear of cabinet.
(Again level should be placed parallel to
cabinet back).
3. Perform similar procedures to steps 1 &
2 by placing the level on inside floor (left
and right sides - parallel to the depth of the
cooler). Level cabinet.
Step C
Draw an outline on the base on the floor.
Step D
Raise and block the front side of the cabinet.
Step E
Apply a bead of “NSF Approved Sealant”, (see list below),
To floor half inch inside the outline drawn. The bead
must be heavy enough to seal the entire cabinet surface
when it is down on the sealant.
Step F
Raise and block the rear of the cabinet
Step G
Apply sealant on floor as outline in Step E. on other three
sides.
Step H
Examine to see that cabinet is sealed to floor around
entire perimeter.
Note:
Asphalt floors are very susceptible to chemical attack. A
layer of tape on the floor prior to applying the sealant
will protect the floor.
NSF Approved Sealants:
1. Minnesota Mining #ECU800 Caulk
2. Minnesota Mining #ECU2185 Caulk
3. Minnesota Mining #ECU1055 Bead
4. Minnesota Mining #ECU1202 Bead
5. Armstrong Cork - Rubber Caulk
6. Products Research Co. #5000 Rubber Caulk
7. G.E. Silicone Sealer
8. Dow Corning Silicone Sealer
CABINET DRAIN
A. True Dipping Cabinets have a drain at the
bottom of the unit. (See image 1). The drain hose
is located behind the rear grill of the unit. (See
image 2). Back out four 1/4" hex head screws to
remove the rear grill when accessing this drain
hose. When cleaning the unit make sure the drain
hose is connected to a garden type hose that is
routed to a floor drain.
Image 1 Image 2
Drain Hose
Cabinet Drain