True Manufacturing Company TDC-47 Freezer User Manual


 
............ www.truemfg.com ............
True Food Service Equipment, Inc.
11
11
TEMPERATURE CONTROL ADJUSTMENT FOR
HIGH ALTITUDE / DEFROST OPERATIONS
TEMPERATURE CONTROL:
(Temperature Control Adjustment For High Altitude
Only!)
Temperature control is located at the back of the
unit next to the rear grill. A flat head screw driver
will need to be used when adjusting the
temperature of the unit. (See image 1).
TERMS:
Cut-out - Temperature sensed by the controller that
shuts the compressor off.
Cut-in - Temperature sensed by the controller that
turns the compressor on.
REQUIRED TOOLS:
• Phillips Head Screwdriver
• 5/64" or 2 mm Allen Wrench
• T-7 Torx Wrench
STEP 1
Unplug the cooler.
STEP 2
Remove the screws that secure the temperature
control to the inset box lower left side of the
cabinet (when facing the front of the cabinet).
STEP 3
Pull out gently from cabinet.
STEP 4
For high elevation installations, it may be necessary
to "warm-up" the set points. To make the
adjustment, insert the appropriate tool in each
adjustment screw and turn 1/4 of a revolution
clockwise (to the right). This procedure will adjust
both the cut-in and cut-out about 2°F warmer.
STEP 5
Make sure to reconnect the pink wire to the proper
spade terminal when reinstalling.
MANUAL DEFROST:
The unit will need to be manually defrosted.
Unplug unit until all frost is gone. The manual
defrost frequency will depend on the units usage,
environment, and the amount of frost.
NOTE:
REMEMBER TO CONNECT DRAIN HOSE TO A GARDEN
TYPE HOSE THAT IS ROUTED TO A FLOOR DRAIN
WHEN MANUALLY DEFROSTING UNIT.
If ice builds up on interior walls- (TDC Units Only)
A. Remove product, unplug and roll unit so defrost
plug is above floor drain (or large flat pan).
B. Remove plug and allow ice to melt and drain.
Do not scrape interior of cabinet to loosen ice,
as this will damage the cabinet. Allow cabinet to
defrost with power off.
C. When ice has melted wipe up and water left in
the freezer floor.
D. Be sure to replace defrost plug before moving
freezer back in position.
E. Allow freezer to refrigerate and cycle before
placing wire baskets and product back into
freezer.
INSTALLATION / OPERATION INSTRUCTIONS
Danfoss Temperature Control (High Altitude Adjustment Only!)
Cut-out Adjustment Screw Allen (5/64"
or 2 mm) (clockwise for warmer)
Cut-in Adjustment Screw Torx (T-7)
(clockwise for warmer)
Compressor Connection
Compressor Connection
(double terminal)
Image 2
Image 1
Temperature
Control