U-Line CLRCO2075 Refrigerator User Manual


 
19
Design
Features
Performance
SERVICING
Mode 4: Ice Harvest (No Refrigeration Possible)
ICE MAKER EVAPORATOR
COMP - COMPRESSOR
CONDENSER
BYPASS
VALVE (UPPER)
VALVE (LOWER)
REFRIGERATION
REFRIGERATOR
EVAPORATOR
CAPILLARY
TUBE
HOT GAS
BYPASS
VALVE
DRYER
DISCHARGE
TUBE
SUCTION
TUBE
ACCUMULATOR
REFRIGERATION
H2O IN -
WATER
SUPPLY
CIRCULATION PUMP
WATER
H2O PUMP -
REF VALVE -
REF VALVE -
HOT GAS -
FAN
CONDENSER
FAN -
Liquid line sensor: Determines length of ice cycle & harvest
RELAY
STATUS ON
COMP
ON
H2O IN REF VALVE*
OFF
FAN
OFF
H2O PUMP
ON
HOT GAS
*Double throw relay: OFF: REF valve closed, REF bypass valve open
ON
ON
OFF
OFF
ON
OFF
ON
DURING HOT-GAS
UNIFORM PRESSURE
FLOW DIRECTION
REFRIGERATION FLOW
NO REFRIGERATION FLOW
HARVEST MODE
OFF
CLRCO043