34
Design
■
Features
■
Performance
SERVICING
8 No ice production
CAUSE REMEDY
a. No water supplied to unit a. Check that water is connected and turned on
b. Stand pipe not inserted in water trough b. Insert stand pipe securely into water trough
9 Low ice production
CAUSE REMEDY
a. High ambient temperatures around unit a. Low ice rate is normal with high ambient
temperatures
b. Deposit build-up on evaporator grid b. Run the unit through a clean cycle
c. Ice thickness dial set incorrectly c. Adjust ice thickness dial
d. Dirty condenser coil d. Clean condenser coil
10 Poor ice quality (unclear cubes)
CAUSE REMEDY
a. Poor incomining water quality a. Consult a plumber
b. Deposit build-up on evaporator grid b. Run the unit through a clean cycle
11 Unit produces shallow or incomplete cubes
CAUSE REMEDY
a. Low water level a. Check that stand pipe is fully seated inside
water trough
b. Low water pressure b. Consult a plumber (pressure should be 20
minimum to 120 maximum psi)
c. Unit is not level c. Level unit to assure even water flow
d. Ice thickness dial set incorrectly d. Adjust ice thickness dial
12 Water leak under unit
CAUSE REMEDY
a. Incoming water supply line leaking a. Check brass connection
b. Fill tube leaking b. Tighten fill tube connection to water line
c. Drain connections not tight c. Check all connections
13 Water in ice bin
CAUSE REMEDY
a. Bin drain kinked or restricted a. Clear drain of obstruction or kink
b. External drain is restricted b. Check drain lines