Design
Features
Performance
ICE THICKNESS ADJUSTMENT
Your U-Line Clear Ice Maker uses advanced technology to make ice that is crystal clear. This
technology cascades a flow of water over a chilled ice mold that is mounted vertically so no water sits in
it. Because of this ice making technology, clear ice cubes differ significantly
from regular ice cubes. Differences are as follows:
Dimples. U-Line clear ice cubes have “dimples” on one
side from the cascading water process.
Cube Variations. Cubes made from different batches, or
even cubes within the same batch may have varying
dimples, thicknesses and/or sizes due to the cascading
water process.
Cube “slabbing.” The U-Line clear ice maker makes a
“slab” of ice that falls from the vertical mold rely-
ing
on gravity to break the ice bridges. Depending
on
the control setting, and the fullness of the ice
bucket, it maybe necessary to tap the ice slab
with the scoop to break it apart.
The ice cube thickness control is factory set for best overall performance. The factory setting is designed to
maintain an ice bridge of approximately 1/16" to 1/8" under normal conditions resulting in a dimple of
approximately 1/4" to 1/2" in depth. A fuller cube with less of a dimple results in a thicker ice bridge. As
the ice bridge becomes thicker, the tendency for the cubes to stay together as a slab increases. A bridge
thicker than 1/8" may cause cubes to overfill the ice bucket.
Cube Types
GOOD
BRIDGE
TOO THIN
BRIDGE
TOO THICK
DIMPLE
TOO DEEP
LITTLE OR
NO DIMPLE
1/4" TO 1/2"
DIMPLE
1/16" TO 1/8"
ICE BRIDGE
BAD
SERVICING
Do not touch electrical wires. Disconnect power to the ice maker before making any ice
thickness adjustments.
!
WARNING
!
DIMPLES
ICE BRIDGE
ICE001
Ice Bridge and Dimples