U-Line CO2075FF Ice Maker User Manual


 
www.U-LineService.com 16 02/2005
CO2075FF — Ice Maker/Refrigerator
Initial Start-Up
Once installation and leveling is complete, the unit is
ready for initial start-up and operation. The ON/OFF
switch is located in the front grille (see Figure 38).
1. Put the ON/OFF switch in
the ON position and set
the Temperature Control
Knob at 4.
2. As soon as the ice maker
mold reaches the proper
temperature, the ice
maker mechanism will fill
the mold with water.
Note: The first cubes may be
small because of air in the
water line. After two hours,
cubes will be standard size.
3. The ice maker will continue to produce until the bin is
full. You may interrupt production by raising the bin
arm into an upright and locked position (see
Figure
39
). While the bin arm is locked, the unit will maintain
temperature for ice storage.
IMPORTANT
It is possible that dirt or scale will dislodge in the water
line. Always throw away all ice cubes made during the
first twenty-four (24) hours of operation.
CAUTION
The ice bucket MUST be fully inserted to avoid freezing
products in the refrigerator section. The ice bin door
must be fully closed with the door lip inside the ice
bucket.
Do not place cans or bottles so they are touching the
back wall of the refrigerator section, as they may
freeze.
Do not place any objects over air inlet or outlet in the
freezer section.
About Settings
No adjustments should be necessary at this time. For
information about Adjusting the Temperature Control
and Adjusting the Cube Size, see the User Manual.
Start-Up Troubleshooting
Problem
Q
:
Unit does not appear to turn on when switch is set to ON.
Solution
A:
Make sure unit is plugged in and outlet has power (circuit
breaker has not tripped). Check to see that light switch
actuator bracket is contacting the light switch properly.
Remember that the ice maker mechanism will not fill the
mold with water until the mold reaches the proper
temperature.
Problem
Q
:
Water does not appear to be flowing into unit.
Solution
A:
Check that the water is connected and turned on and the
line is not obstructed.
Problem
Q
:
The cubes produced during the first two to three hours of
operation have been discarded. New cubes still appear
cloudy.
Solution
A:
This is normal and is caused by air being trapped in the
cube during fast freezing.
IMPORTANT
See the User Manual’s Troubleshooting Guide for more
solutions.
10 Start-Up for the First Time
O
N
OF
F
ON/OFF
Switch
Temperature
Control Knob
WARMER
17
3
4
5
26
COLDER
O
N
OFF
Figure 38
Figure 39