Vulcan-Hart 52424 Pasta Maker User Manual


 
10
LIFT ARM
ADJUSTMENT BOLT
4. Remove temperature dial knob and insert flat head screw driver into the thermostat shaft rotating the
thermostat adjustment screw to match pyrometer reading to 225 degrees F. at the dial boil setting. Turn
clockwise to increase and counterclockwise to decrease setting. One quarter turn will change the
temperature by 18 degrees. (Fig. 2)
Fig. 2
5. Check the temperature cycling again to insure proper calibration.
BASKET LIFT ARM ADJUSTMENT
This procedure is only required if the basket lift arm is not properly raising or lowering the cooker basket into the
water at the correct level.
1. Turn cooker off and allow it to cool.
2. Remove the cooker baskets.
3. Pull lift arm from the cooker.
4. Turn by hand the adjustment bolt to the required position. (Fig. 3)
Fig. 3