F35425 (February 2006)Page 7 of 40
Door Gasket
1. Open the door.
2. Remove screws from the gasket guard and
gasket plate.
3. Remove the gasket guard and the gasket plate.
4. Position the new gasket on the gasket plate.
5. Reverse the procedure to install.
6. Adjust the door as outlined under SERVICE
PROCEDURES AND ADJUSTMENTS.
Damage to the gasket sealing surface, such as nicks
or cuts, will cause steam leakage.
Door Handle
1. Open the door.
2. Remove screws from the top and bottom of the
door.
3. Pull the outer door panel out from the door
housing.
4. Remove the plate, nuts, washers and spacers
from the handle screws and remove the door
handle from the door.
5. Reverse procedure to install. When installing the
spacers, the smaller diameter fits into the slot in
the door and the latch. Use Loctite 271 to secure
fasteners.