Vulcan-Hart MHB24G Electric Steamer User Manual


 
VHX SERIES STEAMERS - GENERAL
F24700 (October 2001)Page 7 of 68
Gas Supply
MODEL
INPUT
(BTU/HR)
MANIFOLD
PRESSURE
(INCHES W.C.)
PILOT
PRESSURE
(INCHES W.C.)
LINE PRESSURE
(INCHES W.C.)
NATURAL PROPANE
MAXIMUM
ALLOWED
NAT. PROP. NAT. PROP. NAT. PROP.
MINIMUM
RECOMMENDED
MINIMUM
RECOMMENDED
VHX24G
200,000 200,000 3.0 3.0 3.5 3.5 7.0 11.0
14.0
270,000 270,000 3.0 3.0 3.5 3.5 7.0 11.0
VHX24G5
200,000 200,000 3.0 3.0 3.5 3.5 7.0 11.0
270,000 270,000 3.0 3.0 3.5 3.5 7.0 11.0
MHB24G
200,000 200,000 3.0 3.0 3.5 3.5 7.0 11.0
270,000 270,000 3.0 3.0 3.5 3.5 7.0 11.0
NOTE
:
1. Output Boiler Horsepower (BHP): 4.3 BHP for 200,000 BTU; 5.5 BHP for 270,000 BTU.
2. Input BTU/HR difference is based on gas orifice size and air orifice size.
TOOLS
Standard
Standard set of hand tools.
Volt-Ohm-Meter (VOM) with AC current tester.
(Any quality VOM with a sensitivity of at least 20,000 ohms per volt can be used)
Gas leak checking equipment.
Gas pressure manometer
Temperature meter and thermocouple.
Special
The recommended deliming chemical for the water treatment system in use, for deliming of the boiler.
Contact Vulcan Authorized Service Centers.
Heat Exchanger Gasket (joint sealant strip, Teflon) P/N 854058-1.