ELECTRIC COMBI OVEN - REMOVAL AND REPLACEMENT OF PARTS
Page 14 of 68
Steam Generator
1. Turn off the water supply to the steam
generator.
2. Remove the right side panel as outlined under
“COVERS AND PANELS”.
3. Remove the thermal fuse and protective sleeve
from the heater thermowell.
4. Disconnect the heating element lead wire
connections.
5. Remove the heating element from the steam
generator by removing the mounting nuts.
NOTE:
When installing a new heater, use the
supplied gasket and ensure the mating surfaces are
clean.
6. Reverse procedure to install.
THERMAL FUSE(S)
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
1. Remove the right side panel as outlined under
“COVERS AND PANELS”.
2. Disconnect the thermal fuse(s) lead wire
connections.
3. Remove the thermal fuse and protective sleeve
from the heater thermowell.
4. Reverse procedure to install.
NOTE
: When replacing thermal fuse, be sure to
insert the protective sleeve and thermal fuse
together. The protective sleeve must
be inserted
into the heater thermowell with the fuse to avoid
chafing of the fuse leads.
NOTE
: When replacing thermal fuse do
not
pull the
lead wires apart. This may break the contact
junction or damage the connections.