Whirlpool KUIA15NRH*11 Ice Maker User Manual


 
3-7
ERROR DISPLAYS
These errors will occur at any time during normal operation if a thermistor fails.
2 Blinks — Service Light is blinking twice in repeating intervals – This signi es a bin thermistor
failure. Check that the bin thermistor is plugged in to the control box. Check that the bin thermis-
tor is not open or shorted. Replace the thermistor if it is open or shorted.
3 Blinks — Service Light is blinking three times in repeating intervals – This signi es a harvest
failure. Check that the evaporator thermistor is connected to the sealed system tubing. If the
thermistor is plugged in, ensure that it is fully connected to the control box. (The ice maker will
operate on a timed cycle if the evaporator thermistor is unplugged.) Check the resistance of the
thermistor. If the thermistor checks good, then look for a frost pattern on the evaporator plate.
The unit may be low on refrigerant.
HOLIDAY MODE
The Holiday Mode feature is designed for the traveler or for those whose religious observances
require turning off the lights and the ice maker. By selecting this feature, ice production and the
interior lights will be disabled. Press and hold the Holiday Mode button to turn on the Holiday
Mode feature. Press and hold the button again to turn off the feature.
The Holiday mode LED is lite constantly in this mode.
Order Component On/Off LED
(On for some
models)
Service LED
(Off for some
models)
Clean LED Feature Light (for
some models)
1 Entry into Test
Mode
ON ON ON ON
2 Bin Thermistor ON Solid--OK
2 blinks--Open
4blinks--Short
OFF OFF OFF
3 Evaporator
Thermistor
OFF OFF ONSolid--OK
2blinks--Open
4blinks--Short
OFF
4a Water Valve
4 min timeout
Service button
press will advance
to step 6
OFF ON Solid--reservoir full
Blinking--reservoir
empty
ON OFF
4b Water Level
Sensor
OFF ON Solid--reservoir full
Blinking--reservoir
empty
ON OFF
5 Recirculation
Pump
ON ON ON OFF
6 Reservoir Drain
Pump
ON OFF OFF OFF
7 Compressor and
Condenser Fan
Motor
ON Solid while cooling Blinking when evap
thermistor reaches
4.5ºF; full frost pattern
should be visible
ON OFF
8 Compressor and
Hot Gas Valve
ON Solid while heating ON Solid while heating
Blinking when evap
thermistor reaches 52ºF
ON Solid while heating OFF
9 Twice Ice OFF OFF ON Solid--Nodelay
Blinking--10min delay
between cycles
Press Clean button to
cyclebetween settings
OFF
10 Ice Thickness OFF 2 Blinks--Thin
4 Blinks--Normal
6 Blinks--Thick
Press Clean button to
cyclebetween settings
OFF OFF
Diagnostic Chart
After pressing any button to enter manual diagnostics all LEDs will illuminate for 5 seconds. The
controls will then automatically move to the rst component.