Whirlpool KUIA15NRH*11 Ice Maker User Manual


 
4-9
REMOVING THE CONDENSER FAN MOTOR
1. Unplug ice maker or disconnect power.
2. Open the ice maker door.
3. Remove the ice from the storage bin.
4. Disconnect the water and drain lines from
the ice maker and remove the unit from its
installation.
5. Remove the four hex-head screws from
the front panel and remove the panel.
6. Remove the two 5/16” screws from the
front of the cabinet.
7. Remove two hex-head screws from the
measured ll water valve bracket.
8. Allow the valve to drop down out of the
way.
NOTE: If the unit you are servicing is equipped
with an internal drain pump, perform steps 9
and 10. If the unit does not have an internal
pump, skip those steps, and proceed to step
11 on the next page.
9. From the back of the unit, remove the four
screws from the unit compartment cover
and remove the cover.
Unit Compartment Cover
4 Screws
Water Inlet Tubing
Measured Fill Water Valve
Hot Gas Valve
Front Panel Screws
Screw
Screw
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
WARNING
Continued on the next page.