Whirlpool KUIA15NRH*11 Ice Maker User Manual


 
5-3
WATER RECIRCULATION PUMP
Refer to page 4-7 for the procedure for access-
ing the water recirculation pump.
1. Unplug ice maker or disconnect power.
2. Set the ohmmeter to the appropriate
scale.
3. Touch the ohmmeter test leads to the
outside water recirculation pump wire
connector pins. The meter should indicate
approximately 3.6 ohms.
RESERVOIR DRAIN PUMP
Refer to page 4-8 for the procedure for access-
ing the reservoir drain pump.
1. Unplug ice maker or disconnect power.
2. Set the ohmmeter to the appropriate
scale.
3. Touch the ohmmeter test leads to the
outside reservoir drain pump wire con-
nector pins. The meter should indicate
approximately 3.6 ohms.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING