Cutting the Hole for the WhisperKOOL Unit
Tools Needed
Sizing the Unit to the Room
Using a level and a pencil, mark a horizontal line
on the wall between the two studs, approximately
1 1/2” (or as close as possible if more than 1 1/2”)
from the ceiling.
Using a ruler or measuring tape, measure 16 1/4”
down, and mark another horizontal line parallel to
the rst one.
Locate the desired installation location. Using a stud nder, locate the studs on either side of the center point,
and mark them with vertical lines.
Using a saw, cut along the uppermost horizontal line
until your saw reaches the stud. Turn the saw around,
inserting it into the cut you have just made, and cut
toward the opposite stud so that you have a clean hori-
zontal cut between the two studs. Be careful not to cut
into the studs themselves.
Now make the second horizontal cut from stud to stud
on the line 16 1/4” below the rst cut.
Hammer
Mark the horizontal lines with a level
SawScrewdriver
Level
Model
5000ti/tiR
Cellar Volume
1000 high
AMP’s
32
31
AMP’s
7.2
6.4
Product Dimensions
14.25” x 16” x 28”
(cubic feet) (starting) (running) (W x H x D)
14.25” x 16” x 28”
5000ti/tiR 1000 low 30 5.9 14.25” x 16” x 28”
5000ti/tiR 1000 med