WhisperKool 5000TIR Refrigerator User Manual


 
Page 25
STANDARD CONTROLLER FUNCTIONS - XR70CX
If your unit is installed through the wall and does not have a remote keypad you will have the XR70CX Controller.
Button Normal Functions
ON/OFF • The ON/OFF button allows the customer the convenience of turning the refrigera-
tion system ON or OFF, from the control panel. This feature does not disconnect
power from the unit. In order for the power to be shut o from the unit, the power
cord must be unplugged from the wall receptacle.
• Press the ON/OFF button once for button application.
Up and Down
Arrows
• Use these buttons to scroll up or down the CPSM (Customer Preference Selection
Mode)
menu.
• Displays the Highest and Lowest temperature sensed by the Bottle Probe. This
feature allows the customer instant access to the recorded data applicable to the
Bottle Probe Temperatures, it can be easily reset to reect current temperatures.
1. Press the “UP” arrow, or the “Down” arrow once, and the Highest or Lowest Tempera-
ture (Hi/Lo) sensed by the Bottle Probe, will be displayed.
2. To reset the Hi/Lo, press and hold the “Set” button when the Hi/Lo value is displayed
on the Digital Display, continue to hold the “Set” button until “rst” appears on the
digital display and then blinks. This will erase the past recorded “Temperature Data
History” and start recording, from the current time and temperature, forward. Tem-
peratures displayed would reect Bottle Probe Temperatures from that point in time,
and beyond.
3. The Hi/Lo feature should be reset at initial “Start-Up” and after the Cellar or Cabinet
has obtained normal operating temperatures, which is generally 55°F.
Cellar PreChill (CPC) The CPC Feature is activated by pressing the Up button for 3-5 seconds, and the CPC
logo will be displayed on the digital display. The CPC feature can be terminated by
pressing the Up button for 3-5 seconds, or the feature will self terminate after 6 hrs.
1. The (CPC) Feature may be used to Pre-Chill the Cellar prior to loading it with Warm
Product. The feature will shift the Set Point down to a lower setting of 52°F, for the
next 6 hours. After the 6 hour time period, the Set Point will automatically return to
the original Set Point.
2. The CPC feature can be conveniently adjusted to the customer’s specic needs, by
accessing the “Customer Preference Select Mode” (CPSM). See Customer Preference
Select Mode Instructions.