WhisperKool 5000TIR Refrigerator User Manual


 
Page 24 PT-EXPL5000 060311
Initial Start-Up
When power is applied to the unit, the control will
briey display all symbols, and the Compressor sym-
bol will be displayed (if unit is calling for cooling).
There may be a brief delay prior to the evaporator and
condenser fans turning on, as the fans will not turn on
until the sensors reach their perspective start tempera-
tures (below 120°F for the evaporator and condenser).
When the evaporator and condenser fans are activat-
ed the “FAN” symbol will turn on.
Normal System Cycle
After the bottle probe has reached the set point (all
units are shipped with the set point of 55°F and a
dierential of 1°F), the unit will turn o. The Whis-
perKOOL Humidity Management (WHM) is an adjust-
able feature which allows the customer the conve-
nience of managing the humidity enhancement of
their wine cellar. The WHM is one of the many Cus-
tomer Preference Selection features which allow the
customer the ability to ne tune the controls. Feature
is o from the factory but can be turned on with the
“FON” parameter.
Anti Short Cycle
The Anti Short Cycle ensures that the compressor
will remain o for a period of 3 minutes after the unit
has reached the set point to allow the pressure in the
refrigeration system to equalize prior to starting the
compressor.
Defrost Cycle
The Defrost Cycle is a precautionary measure, as icing
or frosting of the coil does not occur during normal
operation. The system will go through a defrost cycle
when the evaporator temperature reaches 26°. Dur-
ing the defrost cycle, the indoor fan will provide air
ow across the indoor coil, which will evaporate any
frost accumulation.
Bottle Probe Failure Protection
In the event that a bottle probe should fail, the APST
(Advance Product Safety Technology) will automati-
cally transition the Refrigeration Compressor cycles
to a pre-determined time series (based on detailed
laboratory testing), which will ensure that the product
is kept within the safe range.
Remote Control Panel (optional)
The control panel can be installed or mounted sepa-
rately from the cooling unit itself (remotely), using the
supplied cable. This option provides unique exibility
for installing the Extreme Series cooling unit in your
wine cellar. The remote option must be specied when
the unit is ordered.
Note: Remote Control is generally standard with a
“Ducted Unit”.
Ducting and Ventilation Options
The ventilation system is ideal for ducting. The option-
al collars t standard ventilation ducting allowing the
installer to vent air to and from the unit for optimum
performance (please see specications for details).
SYSTEM OPERATION:
Standard and Remote Controllers