Xantrex Technology 815-3024 Microwave Oven User Manual


 
97-0019-01-01 21
Operating the Freedom SW with the SCP
Figure 8 Xanbus System Control Panel (SCP)
Item Description
1 AC In/Charge LED indicates that qualified AC is
present at the input of an inverter/charger. When the
Freedom SW is connected to a qualified AC source
like the utility grid or a generator, this LED on the
SCP turns on.
Xanbus System Control Panel (SCP)
FGA :809-092 1
ACIn/Charge
Inverter On
Low Batt er y
Faul t
STBY/ON
Fault Cl ear
TM
Enter Func
2
1
4
3
10 9 8 7
5
6
2 Inverter On LED turns on when the Freedom SW
is inverting using battery power.
3 Low Battery LED turns on when the battery
voltage on the Freedom SW is low.
4 Fault LED indicates a detected condition that
requires user attention and intervention. The Fault
LED turns on when any Xanbus-enabled device
connected to the network detected a fault. See
“Detected Fault Types” on page 72 for the
definitions of a fault and warning.
5 STBY/ON Fault Clear button is used to clear
active faults on the system if pressed momentarily.
It also toggles all Xanbus-enabled devices on the
system between Operating and Standby (Power
Save) mode when held down for more than five
seconds. See “Inverter Operation Using the Front
Panel” on page 16.
6 Screen displays menus, settings, and system
information. Displays a menu screen title, four lines
of menu items, and a line that contains small arrows
that depict pointers to SCP buttons.
Item Description
Freedom SW 3K2K InvChg Owners Guide.book Page 21 Thursday, July 31, 2014 1:42 PM