Xantrex Technology 815-3024 Microwave Oven User Manual


 
60 Freedom SW Owner’s Guide
Configuring the Freedom SW using the SCP
Cascading
The Cascading feature is found in the System Settings menu
only when two inverters are configured as a stacked pair (see
“Stacking Configuration Menu” on page 57). A stacked pair has one
Master unit and one Slave unit. The cascading feature allows
manually entered inverter/charger settings on the Master unit to be
automatically cascaded (or copied) to the Slave unit when the two
units are meant to have the same settings. Cascading helps simplify
the duplication of settings of one inverter into another. The feature
is Enabled by default but may be Disabled to accommodate
different settings for the Master and Slave units. Review with a
qualified system designer before adopting different settings for the
Master and Slave units.
To change Cascading settings:
1. From the System Status screen, press the Enter button.
The Select Device menu screen appears.
2. From the Select Device screen, press the Enter button.
The System Settings menu screen appears.
3. From the System Settings screen, press the Down arrow
button to highlight Cascading.
4. Press Enter and use the Up and Down arrow buttons to change
selections.
5. Press Enter again to choose a selection.
6. Press Func (3x) to return to the System Settings menu.
Select Device
System Settings
FSW3012 00
XAGS 00
XSCP
System Status
Battery
BatLev
Load
AC In
12.1V -257A 84F
Invert
120V 12A
0V 0A
menu EnInv EnChg Shr
System Settings
Invert
AC Charge
System Mode
Cascading [Enabled]
12
3
Steps 4 to 6 are not shown.
Freedom SW 3K2K InvChg Owners Guide.book Page 60 Thursday, July 31, 2014 1:42 PM