18
PRE-INSTALLATION CHECKS
MODEL:
Exmoor – YM-W9001FL / YM-W9001LC / YM-W9001ERFL / YMW9001ERLC
Exe – YM-W9101FL / YM-W9101LC / YM-W9101ERFL / YMW9101ERLC
YM-W9102FL / YM-W9102LC / YM-W9102ERFL / YM-W9102ERLC
Devon – YM-W9201FL / YM-W9201LC / YM-W9201HC / YM-W9201ERFL /
YM-W9201ERLC / YM-W9201ERHC / YM-W9202FL / YM-W9202LC /
YM-W9202HC / YM-W9202ERFL / YM-W9202ERLC / YM-W9202ERHC
County – YM-W9301FL / YM-W9301LC / YM-W9301HC / YM-W9302FL/
YM-W9302LC / YM-W9302HC
Exmoor
Exe
Devon
County
Flue/Chimney Size
Without flue liner Round
(diameter)
mm 150 150 150 150
inch 6 6 6 6
Without flue liner system
Square (diameter)
mm 135 135 135 135
inch 5
1
/
2
5
1
/
2
5
1
/
2
5
1
/
2
With liner or Factory made
system (diameter)
installed in accordance with manufacturer's instructions
mm †150 150 150 150
inch †6 6 6 6
Flue/Chimney
(*minimum height)
All products
metre 4.5 4.5 4.5 4.5
feet 15 15 15 15
* When measured from the top of the stove to the top of the flue, with no
horizontal sections and a maximum of 4 bends with angles of less than 45
o
†May be 125mm (5") if only burning low volatiles (smokeless) fuels approved for use in Smoke Control Areas.
See web sit http://uksmokecontrolareas.co.uk for more information about approved fuel
1. FLUES
2.1 Additional ventilation is required to comply with the
requirements of the Building Regulations. This must be
provided using a permanently open air vent, of the size
listed, which is positioned so that it is not liable to be
blocked both inside and outside the building.
2.2 Extractor fans or cooker hoods must not be placed in the
same room or space as this can cause the appliance to emit
fumes into the room.
2.3 If any of these checks reveal problems do not proceed
with the fitting of the appliance until they have been
rectified.
2. ADDITIONAL VENTILATION
MODEL:
Exmoor – YM-W9001FL / YM-W9001LC / YM-W9001ERFL / YMW9001ERLC
Exe – YM-W9101FL / YM-W9101LC / YM-W9101ERFL / YMW9101ERLC
YM-W9102FL / YM-W9102LC / YM-W9102ERFL / YM-W9102ERLC
Devon – YM-W9201FL / YM-W9201LC / YM-W9201HC / YM-W9201ERFL /
YM-W9201ERLC / YM-W9201ERHC / YM-W9202FL / YM-W9202LC /
YM-W9202HC / YM-W9202ERFL / YM-W9202ERLC / YM-W9202ERHC
County – YM-W9301FL / YM-W9301LC / YM-W9301HC / YM-W9302FL /
YM-W9302LC / YM-W9302HC
Exmoor
Exe
Devon
County
Additional Ventilation
mm
2
0 0 2200 4400
cm
2
0 0 22 44
in
2
0 0 3.41 6.82