2727
MAINTENANCE and SERVICING
PR7531
Seal 12x3
Seal 14mm
2 Door
7.3 Remove the old rope and scrape old glue from the locating
grooves. Clean the locating groove with a clean dry cloth to
remove all old dust and debris.
7.4 Squeeze a generous bead of fresh Stovax Thermic Seal glue
into the rope locating groove (part no. 5037). Press the new
Stovax rope into the locating groove, placing the joint in the
middle of the lower edge of the door (one door version
only).
7.5 Refit and close the door to apply pressure to new rope.
Leave the stove closed for at least 12 hours before lighting
the stove and use at a low output for approximately one
day. This allows the adhesive to bond fully.
7.6 Using the stove with a damaged door seal could cause
dangerous fumes to enter the room, or the stove to over-
fire, resulting in damage.
7.7 If you require help, your local Yeoman dealer will be able
to carry out all of your service and maintenance
requirements for a reasonable cost.
8. ADJUSTING DOOR HINGES
(EXMOOR MODELS ONLY)
8.1 To maintain the safe use of your Yeoman Exmoor stove, you
may need to adjust the door hinges to ensure safe correct
closing of the door. Complete this operation as follows.
8.2 Open the door to give access to the fixed part of the door
hinge as shown.
PR7532
Fixing Nut
Fixing Nut
8.3 Using a 13mm A/F spanner loosen the fixing nuts, as shown,
and reposition the hinge blocks to achieve a correct fit. This
may require a trial and error approach to find the correct
position.
9. ADJUSTING DOOR CATCH
(ALL MODELS)
9.1 To adjust the fit of the door catch rotate the door knob
clockwise to loosen the fit or anti-clockwise to tighten the
fit. This adjustment should be made in steps of one full turn
of the door knob. The flat edge of the door cam should be
parallel with the door opening on the stove body when the
door is open.