Configuring PAD/ATPAD Ports 21
PAD Port Configuration
SDLC Mnemonic
Addressing
Calls placed in a port configured for SDLC must use the mnemonic calling feature.
Figure 3 shows the configuration process for calls on SDLC ports. Station 2, Port 4
in Node 100 is configured to call Station 3, Port 3 in Node 200.
Figure 3. SDLC Mnemonic Autocall Addressing
Note
These configuration records and parameters pertain only to SDLC Mnemonic
Autocall Addressing. There are also others that must be configured.
PB S200
PB S200
Station 1
Station 2
Station 3
Station 1
Station 2
Station 3
SLDC
Port# 04
HPAD
SLDC
Port# 3
TPAD
Node 100
(Node Address 10000)
Node 200
(Node Address 20000)
X25-4 X25-5
Port Record
Port Number: 4
Port Type: SDLC
Sub Type: HPAD*
SDLC Station Record
Port Number: 4
Station Number: 2
Autocall Mnemonic: Mnemonic
Station Subaddress: 2
Mnemonic Table Record
Mnemonic Name: Mnemonic
Call Parameters: 20000303
Route Selection Table
Address=: 200
Destination: X25-1
Priority: 1
Port Record
Port Number: 3
Port Type: SDLC
Sub Type: TPAD*
SDLC Station Record
Port Number: 3
Station Number: 3
Autocall Mnemonic: (Blank)
Station Subaddress: 3
Route Selection Table
Address=: 20003
Destination: SDLC-3S3
Priority: 1