DSM250 User’s Manual
Page 180 Revision 1.4.16a
The next step in the calibration process is to fill the tank and indicate the volume of fluid in the tank at
various points while filling the tank. This process should be started with an empty tank. You only need
to indicate two calibration points for a rectangular tank, and can use up to 16 calibration points for a
tank with a more complex shape. Figure 206 shows a screenshot of the first calibration step. Enter
the first calibration point with an empty tank (0.0 Gallons
/liters) by pressing the Accept key. The
“Current Point” highlight will advance to the next point.
Figure 206 – Empty Level Calibration
Each time you press Accept during this process and after the Current Point highlight advances, put
more fluid into the tank, and note the total volume of fluid pumped into the tank at this point. Use the
Increase and Decrease keys to set the current tank level to the appropriate value, and then press the
Accept key to store the current calibration point and advance to the next calibration point. Figure 207
shows a screenshot of these intermediate calibration points.
Figure 207 – Intermediate Level Calibration