Revision 1.4.16a Page 223
®®
Figure 262 – Trigger Configuration – Data Unavailable Alert
Re-trigger Period – When you accept an alert, it will change to the “Accepted” state, and
annunciators that are sounding for that alert will stop sounding. If the condition which caused
the alert remains true after the amount of time in this field, the alert will return to the “Active”
state, and annunciators will begin sounding again for that alert. If a value of 0:00 is entered,
then the alert will never re-trigger.
Alert Set Delay – If the switch being monitored is in the Off state for the amount of time specified
in this field, the alert will become active.
Alert Clear Delay – If the switch being monitored is in a state other than “Off” for the amount of
time specified in this field, the alert will become inactive.
8.3.7.6 Trigger Type is Error Alert
When monitoring circuit breakers, the error alert can be used to raise an alert when the circuit breaker
trips due to over current. As with the On and Off alerts, the Set Delay and Clear Delay values are
used to prevent spurious triggering.
8.3.7.6.1 Trigger Configuration