Tx and Rx are used for RS232 communication. Txd +/
communication. Refer to RS
485 cabling and connection d
There are two Remote modes:
In this mode, return to lo
cal can be made by the front panel REM/LOC or via
serial port command RMT 0. Set the unit into Remote mode via serial port
2. Local Lockout: In this mode the unit can be returned to Remote mode via the ser
command or by turning off the AC power until the display turns off, and then turn
it to on again. In local Lockout mode, the front panel REM/LOC button is not a
tive. Set the unit into Local Lockout mode via serial port RMT 2 co
232/RS485 port in Local mode
When the power supply is in Local mode, it can receive queries or commands. If a query is received,
the power supply will reply and remain in Local mode. If a command that affects the output is r
ceived, the power supply will p
erform the command and change to Remote mode.
Serial commands may be sent to set the status registers and read them while the unit is in Local
mode. If the Enable registers are set (refer to Section 7.11) the power supply will transmit SRQ’s while
Front panel in Remote mode
Front panel control in Remote mode is Disabled except for:
1. PREV: use to preview the Voltage and Current setting.
2. OVP/UVL: use to preview the OVP/UVL setting.
LOC/REM: use to set the unit into Local mode.
out mode, only the PREV and OVP/UVL pushbuttons are active.
7.3 REAR PANEL RS232/RS485 CONNECTOR
The RS232/RS485 interface is accessible through the rear panel RS232/RS485 IN and RS485 OUT
connectors. The connectors are 8 contact RJ
nnectors are used to connect
power supplies in a RS232 or RS485 chain to a controller. Refer to Fig. 7
Fig.7-1: Rear panel J3 IN/OUT connectors pinout