39
• The wire coloured green and yellow must be connected to the termi-
nal marked with the letter “E“ or by the earth symbol E or coloured
green and yellow.
• The wire coloured blue must be connected to the terminal “N“ or col-
oured black.
• The wire coloured brown must be connected to the terminal marked
“L“ or coloured red.
• Upon completion there must be no cut, or stray strands of wire
present and the cord clamp must be secure over the outer sheath.
1 WARNING! A cut off plug inserted into a 13 amp socket is a seri-
ous safety (shock) hazard. Ensure that, if it is necessary to cut off
the plug, it is disposed of safely and not retained.
Connecting systems
The water inlet hose, drain hose and the mains cable must all be con-
nected to the side of the dishwasher as there is no space for them be-
hind the appliance.
2 connection pieces 45° or
straight, outer ø 19 mm,
length 30 mm
double valve water-
drainage
water
inlet
water-
inlet
mains
cable
water-
drainage
mains socket mains cable