AIR SUPPLY
AIR SUPPLY
Installation of this appliance must include a
provision for an adequate flow of fresh air for gas
combustion. This requirement must be observed
by the installer as well as the operator. The rear of
the appliance provides air supply access for gas
combustion and must be kept clear at all times
.
Make certain the installation maintains adequate
air ventilation to provide cooling for electrical and
gas components. The area around the appliance
should be clear of any obstructions which might
retard the flow of cooling air. Failure to observe
this caution may result in damage to the control
components and will void the warranty.
Local and the National Fuel Gas Code provide
rules for determining the amount of fresh air
necessary for combustion and ventilation of
commercial cooking appliances. The codes will help
determine if additional outside air may be necessary
to meet health and safety regulations.
AIR ADJUSTMENTS
Theappliancecanbeeldconvertedfromonetypeof
gas to another (natural gas to propane or vice versa).
After taking the necessary safeguards for the gas circuit
by employing the shut-off valve located at the rear of the
appliance, and disconnect the appliance from the electric
supply. Open the right-hand machine compartment.
Replaceoricesasshowninchart.
Replace valves located under access panel.
Set manifold pressure as shown in chart.
Ifanygasttingsarelooseorhavebeenreplaced,perform
the following test:
q Useasoapandwatersolutiontocheckallttingsfor
leaks. Brush solution on all joints or areas where a leak
maybepresent.Ifbubblesappear,re-tightenthetting
andrecheck.Ifbubblespersist,replacethetting.
Always reconnect the gas line and inspect for leaks before
replacing access panels.
NATURAL PROPANE
Top Orice
OR-28127
# 29
OR-28132
# 43
Middle Orice
OR-28128
# 20
OR-28191
# 41
Bottom Orice
OR-28129
# 1
OR-28130
# 38
Manifold Pressure 5.0 µ/wc 10.0 µ/wc
CAUTION
DO NOT USE CIRCULATING FANS
ON THE FLOOR. FLOOR FANS WILL
AFFECT BURNER OPERATION.
OPTIONAL CONVERSION KITS
Natural Gas to Propane 5008903
Propane to Natural Gas 5008904
CAUTION
CONVERSIONS MUST BE
PERFORMED BY A CERTIFIED
SERVICE TECHNICIAN QUALIFIED TO
WORK ON GAS APPLIANCES.
CAUTION
MAKE CERTAIN THE AREA AROUND
THE REAR OF THE APPLIANCE IS
KEPT CLEAR OF OBSTRUCTIONS TO
ALLOW A CONTINUOUS SUPPLY OF
FRESH AIR FOR GAS COMBUSTION.