AR-6G Rotisserie Operation & Care Manual • 7
INSTALLATION
AR-6G Rotisserie Operation & Care Manual • 7
POSITIONING REQUIREMENTS
q In order to ensure proper ventilation, a minimum
distance of at least 18" (457mm) must be kept from
the side panels (left and right) of the appliance and
any adjoining surfaces.
NOTE: If adequate service clearance is not provided,
it will be necessary to disconnect the gas
connection to move the appliance. Charges in
connection with inadequate service access are
not covered under warranty.
q Allow a minimum clearance of 4" (102mm) from the
back of the appliance for gas plumbing connections.
q Allow a 20" (500mm) clearance at the top of the
appliance for free air movement and for the vent(s)
located at the top.
q Do not install the appliance adjacent to heat producing
equipment such as fryers, broilers, etc. Heat from
such appliances may cause damage to the Electrical
Components of the appliance. Minimum clearance
recommended: 20" (500mm)
Place the appliance on a stable, noncombustible level
horizontal surface. Level the appliance front-to-back and
side-to-side by means of the adjustable casters.
q Rear of unit should be slightly elevated via caster
adjustment to allow the doors to remain open while
operator is working in the unit.
SITE INSTALLATION
79" (1999mm)
18"
(457mm)
18" (457mm)
77-1/2"
(1969mm)
20"
(508mm)
4"
(102mm)
4"
(102mm)
45" (1140mm)