Alto-Shaam AR-6G Convection Oven User Manual


 
AR-6G Rotisserie Operation & Care Manual • 13
INSTALLATION
AR-6G Rotisserie Operation & Care Manual • 13
GAS CONNECTIONS
Theminimumsizeofthegaspipingorexibleconnector
is 3/4" (19mm). For long runs of gas piping, the pipe
diameter must conform to the tables in the National Fuel
Gas Code, ANSI/NFPA Z223.1
A listed gas shut off valve must be installed upstream of
the appliance for shutting off the gas supply while servicing.
This valve should be installed so that it is accessible with the
appliance in the normally installed position.
The appliance is supplied with casters, therefore,
installationmustbemadewithaexibleconnectorthat
complies with the Standard for Connectors for Movable
Gas Appliances, ANSI Z21.69; or in Canada, Connectors
for Movable Gas Appliances, CAN/CGA-6.16-M87. When
usingaexibleconnector,aquickdisconnectdevicemust
also be used that complies with the Standard for Quick-
Disconnect Devices for Gas Fuels, ANSI Z21.41;
or in Canada, Quick Disconnect Devices for Use with
Gas Fuels, CAN1-6.9.
Whenaquickdisconnectdeviceandexibleconnectorare
used, a restraining device must be installed to limit the
movement of the appliance in order to prevent damage to
the connector or quick disconnect. An example of such a
system uses 2000 pound test stainless steel cable attached
to a structural member of the kitchen wall behind the
unit. The attachment means must include a quick connect
snap that can be disconnected when the appliance must
be moved away from the wall. The other end of the cable
should be permanently attached to the rear frame of the
appliance.Thecableshouldbeofsufcientlengthsothat
nostrainiseverplacedupontheexiblegasconnector
if the appliance is accidentally moved without initially
disconnecting the gas connector.
GAS PIPING MUST NEVER BE INSTALLED TO RUN
UNDER THE BURNER.
Theexibleconnectorshouldberoutedtoforma
downward “U” loop between the building gas supply and
the permanent attachment at the rear of the oven.
Theroutingoftheexibleconnectormustnotbemade
under the oven. Oven temperatures achieved during
operation are too hot for safe operation. Gas piping should
be installed from the point of gas connection at the bottom,
frontoftheoventothebackoftheovenwheretheexible
connector may be safely used. See the illustration for the
recommended placement.
WARNING
GAS PIPING MUST NEVER
BE INSTALLED TO RUN
UNDER THE BURNER
.
SECURING ELECTRICAL ACCESS COVER
After gas pressure has been set and leak testing performed,
the electrical access cover located under the drip tray inside
the unit must be sealed with a High-Temperature NSF
Approved RTV adhesive prior to cooking in the unit.
Secure the electrical access panel by applying the High-
Temperature NSF Approved RTV adhesive to each of
the 14 bolts (provided with unit) and tighten down. Next
run a bead of the High-Temperature NSF Approved RTV
adhesive around the electrical access panel and smooth in
place. Wipe excess RTV adhesive off.