Alto-Shaam AR-6G Convection Oven User Manual


 
AR-6G Rotisserie Operation & Care Manual • 11
INSTALLATION
AR-6G Rotisserie Operation & Care Manual • 11
GAS CONNECTIONS
This gas appliance has been set to operate with either
naturalgasorpropaneasindicatedontheidentication
name plate. Make certain the gas supply matches the
nameplate information. Should conversion to the opposite
fuel be desired, conversion parts must be ordered from
thefactory.Conversionmustbecompletedbyaqualied
servicepersononly.Alwaysremembertoreectthe
conversion on the nameplate.
GAS SPECIFICATIONS
NATURAL GAS PROPANE GAS
AR-6G 195,000 Btu/hr. 195,000 Btu/hr.
INSTALLATION REQUIREMENTS
GAS CONNECTION: 3/4" NPT
CHECK PLUMBING CODES FOR PROPER SUPPLY
LINE SIZING TO ATTAIN MINIMUM BURNER
MANIFOLD PRESSURE SHOWN:
NATURAL GAS: 5" W.C.
PROPANE GAS: 10" W.C.
MAXIMUM INLET PRESSURE: 14" W.C.
NOTE:Ifaexiblegaslineisused,itmustbeAGA
approved, commercial type and at least 3/4" I.D.
HOOD INSTALLATION IS REQUIRED
GAS VALVE MAY REQUIRE FIELD ADJUSTMENT
ABOVE 3,250' (991m)
AND IS NOT ADJUSTED AT THE FACTORY.
GAS PRESSURE CHART
The appliance has been factory adjusted according to the
gastypespeciedontheidenticationnameplate.
TECHNICAL SPECIFICATIONS
Natural Gas
Min. Connected
Pressure
7.0" W.C. 1.12 kPa
Max. Connected
Pressure
14.0" W.C. 3.5 kPa
Propane Gas
Min. Connected
Pressure
11.0" W.C. 1.99 kPa
Max. Connected
Pressure
14.0" W.C. 3.5 kPa
DANGER
CONNECTING TO THE WRONG GAS
SUPPLY COULD RESULT IN FIRE OR
AN EXPLOSION CAUSING SEVERE
INJURY AND PROPERTY DAMAGE.
CAUTION
RESIDENTIAL GAS CONNECTIONS
AND HARD-PIPED GAS CONNECTIONS
DO NOT MEET NSF CERTIFICATIONS
WARNING
TO AVOID SERIOUS PERSONAL
INJURY, installation of this appliance
must conform to local, state, and
national codes; the current edition
of the American National Standard
Z223.1, National Fuel Gas Code, and
all local municipal building codes.
In Canada, installation must be in
accordance with Standard CAN/CSA
B 149.1 and Installation Codes - Gas
Burning Appliances, and local codes.