Alto-Shaam AR-7E Convection Oven User Manual


 
AR-7E Rotisserie Operation & Care Manual 5
I N S TA L L AT I O N
The appliance must be installed by a qualified
s
ervice technician. The oven must be properly
grounded in accordance with the National Electrical
Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is easily
accessible in case of an emergency. Arcing will occur
when connecting or disconnecting the unit unless all
controls are in the
OFF position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed by a
licensed electrician in accordance with applicable
local electrical codes.
After wiring and power connection has been
completed, turn the main power switch to the ON
position. The main power switch can be left ON
for daily use, but should be turned OFF when
cleaning or performing maintenance or repairs to
the rotisserie.
E LE C TR I C AL C O NN E CT I ON
“WARNING” RISK OF FIRE!
Use a UL Listed grounding type plug rated 250 Volts, 50
Amperes, 1 Phase, 3 wire for single phase units and 250
V, 50 A, 3 Phase, 4 wire for three phase units. Plug to
be selected and installed only by qualified service
personnel. Individual conductors are marked L1, L2, L3
when applicable, N when applicable, and G.
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
D A N G E R
APPLIANCES WITH NO CORD
PROVIDED BY FACTORY MUST BE
EQUIPPED WITH A CORD OF
SUFFICIENT LENGTH TO PERMIT
THE AP PLIANCE TO BE MOVED
FOR CLEANING.
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE EL ECTRICAL CODES.
E
LECTRICAL
V
OLTAGE
P
HASE
C
YCLE
/H
Z
A
MPS
KW
208 (A
GCY
) 1 60 40.0 8.3
B
ARE END
NO PLUG
240 (A
GCY
) 1 60 38.0 8.8
208 (A
GCY
) 3 60 33.0/ph 8.3
BARE END
NO PLUG
240 (AGCY) 3 60 32.0/ph 8.8
380-415 (AGCY) 3 50 24.0/ph 8.8
N
O CORD
NO PLUG
380 3 50 22.0/ph 7.4
415 3 50 24.0/ph 8.8
Hard wired models:
Hard wired models must be equipped with a
country certified external allpole disconnection
switch with sufficient contact separation.
If a power cord is used for the connection of the
product an oil resistant cord like H05RN or H07RN
or equivalent must be used.
REGARDING INTERNATIONAL STANDARD UNITS:
If the unit is not equipped with flexible cord with
plug, an all-pole country approved disconnection
device which has a contact separation of at least 3mm
in all poles must be incorporated in the fixed wiring
for disconnection. When using a cord without a plug,
the green/yellow conductor shall be connected to the
terminal which is marked with the ground symbol. If
a plug is used, the socket outlet must be easily
accessible. If the power cord needs replacement, use
a similar one obtained from the distributor.
For 230V units: To prevent an electrical shock hazard
between the appliance and other appliances or metal
parts in close vicinity, an equalization-bonding stud
is provided. An equalization bonding lead must be
connected to this stud and the other appliances /
metal parts to provide sufficient protection
against potential difference. The terminal is
marked with the following symbol.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
NOTE: 230V appliances must be connected
to an electrical circuit that is
protected by an external GFCI outl et.
Wire diagrams are located in the inside access panel of the unit
Power Cord Connection: The side connection
is recommended for all applications. If a bottom
connection is necessary for counter top units, user
will need to provide a cutout in the countertop to
allow the cord to hang freely without crimping.